تصبح خبير تحكم السوائل المرتفع من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  Suncenter test nitrogen pumps at discount for natural gas boosts pressure
Suncenter test nitrogen pumps at discount for natural gas boosts pressure

Suncenter test nitrogen pumps at discount for natural gas boosts pressure

موك
1 Set
اسم العلامة التجارية
SUNCENTER
شهادة
ISO/CE/SGS
ضمان
13 Months
التعبئة والتغليف
By Plywood case
ميناء الشحن
Shenzhen/Hongkong
قسط
T/T,Western Union,Credit card.
طريقة المعاملة
EXW,FOB,DDP,CIF,CFR
مكان المنشأ
Guangdong Province, China (Mainland)
موعد التسليم
Within 10-15 working days after received deposit
الأسعار
latest_price
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:
Product Details
We are confident about the exquisite details of gas booster.
Company Advantages
1. The design of Suncenter nitrogen pumps is carefully considered from the perspective of users.
2. Strict quality control processes are carried out throughout the production process, eliminating possible defects in the product.
3. Strict quality control process ensures zero defects and consistent quality.
4. The robust sale growth indicates the bright future of the product.

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter test nitrogen pumps at discount for natural gas boosts pressure-1



The hottest selling- Model C frame type cabinet picture


Suncenter test nitrogen pumps at discount for natural gas boosts pressure-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Suncenter test nitrogen pumps at discount for natural gas boosts pressure-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Company Features
1. With high quality support, Dongguan Suncenter Fluid Control Equipment Co., Ltd is reliable by clients.
2. nitrogen pumps is manufactured using proven and cost-effective production processes.
3. Dongguan Suncenter Fluid Control Equipment Co., Ltd has the strong professional team to solve your all problems. Contact! Dongguan Suncenter Fluid Control Equipment Co., Ltd will never stop and build the road to innovative [核心关键词 design. Contact! Our spirit of pursuing excellent quality and best service makes our pressure booster pump popular and win a high reputation among our customers. Contact! Where there is a need from customers, Dongguan Suncenter Fluid Control Equipment Co., Ltd will provide timely help. Contact!
The structure of hydraulic pump test bench is compact, the disc is flexible and stable during lifting operation, no locking phenomenon occurs, the installation is simple and convenient, and it can be used in horizontal or vertical pipelines.
nitrogen pumps Exquisite design, reasonable structure, exquisite workmanship, beautiful appearance, safe to use, easy to carry, easy to clean and maintain, can easily meet your outdoor barbecue and picnic needs.
The cabinet of nitrogen pumps is made of high-quality stainless steel, which is sturdy, beautiful and durable, safe to use and reliable in quality.
pressure booster pump The design is scientific and reasonable, the structure is tight and compact, the texture is firm and thick, the quality is safe and reliable, the feeding port is large, and the power consumption is low, which can ensure long-term safe and stable operation.
pressure booster pump Made of high-quality materials and precise components, and exquisite technology and craftsmanship, it is compact in structure, reliable in quality, easy to install, easy to operate, beautiful and practical.
This product is not easy to get corroded. Its specially coated surface makes it not prone to oxidation in humid environments. This product has a compact and robust design