تصبح خبير تحكم السوائل المرتفع من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  Suncenter system nitrogen pumps order now for safety valve calibration
Suncenter system nitrogen pumps order now for safety valve calibration

Suncenter system nitrogen pumps order now for safety valve calibration

موك
1 Set
اسم العلامة التجارية
SUNCENTER
شهادة
ISO/CE/SGS
ضمان
13 Months
التعبئة والتغليف
By Plywood case
ميناء الشحن
Shenzhen/Hongkong
قسط
T/T,Western Union,Credit card.
طريقة المعاملة
EXW,FOB,DDP,CIF,CFR
مكان المنشأ
Guangdong Province, China (Mainland)
موعد التسليم
Within 10-15 working days after received deposit
الأسعار
latest_price
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:

Gas booster pump system


Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


Suncenter system nitrogen pumps order now for safety valve calibration-1


DGS booster system = booster pump+ following valves, gages, and parts


Suncenter system nitrogen pumps order now for safety valve calibration-2



The hottest selling- model A and model C cabinet picture


Suncenter system nitrogen pumps order now for safety valve calibration-3
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGS-DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


Technical specification for DGS-DGD Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGS-DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


Technical specification for DGS-2DGD Series:


Model

Pressure boost ratio

Min. gas
   Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

DGS-2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

DGS-2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

DGS-2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


Technical specification for DGS-DGT Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGS-DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


Technical specification for DGS-2DGT series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

DGS-2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

DGS-2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

DGS-2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )


Suncenter system nitrogen pumps order now for safety valve calibration-4



Suncenter system nitrogen pumps order now for safety valve calibration-5
  • DGS series gas boosters working pictures


Suncenter system nitrogen pumps order now for safety valve calibration-6


DGS-DGD40 gas booster system for nitrogen gas spring filling

Suncenter system nitrogen pumps order now for safety valve calibration-7


DGS-DGT series gas boosters for gas cylinder transfer and filling


video





The design of Suncenter nitrogen pumps is strictly conducted. It mainly covers the mechanical structure, spindles, and drive system, control and inspection systems, etc. The product can run super smoothly and noiselessly
The development of Suncenter nitrogen pumps adopts advanced technologies. They include computer-aided design, CNC machining, and sensor control technology. The product is very safe to operate
Advanced machining techniques have been adopted in Suncenter air pressure test bench production. It is fabricated under CNC machining, electrical discharge machining (EDM), laser cutting, and other treatments. The product ensures stable and reliable performance
Quality debugging will be carried out when Suncenter air pressure test bench is produced. The debugging aspects include parts' connection, configuration, structural stability, and other mechanical performance. The product is very safe to operate
Suncenter air pressure test bench goes through serious quality testing after it is produced. It has been certified under many international standards including CCC, CE, and RoHS. The product adopts a water cooling system for better performance
The product is highly resistant to rust. Its surface has been treated with an oxide protective layer to prevent the damage of wet environments. The product is characterized by a high resolution
product_message
دردشة على الإنترنت 编辑模式下无法使用
اترك رسالتك inputting