تصبح خبير تحكم السوائل المرتفع من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  Suncenter stable hydrostatic pressure test marketing for safety valve calibration
Suncenter stable hydrostatic pressure test marketing for safety valve calibration

Suncenter stable hydrostatic pressure test marketing for safety valve calibration

موك
1 Set
اسم العلامة التجارية
SUNCENTER
شهادة
ISO/CE/SGS
ضمان
13 Months
التعبئة والتغليف
By Plywood case
ميناء الشحن
Shenzhen/Hongkong
قسط
T/T,Western Union,Credit card.
طريقة المعاملة
EXW,FOB,DDP,CIF,CFR
مكان المنشأ
Guangdong Province, China (Mainland)
موعد التسليم
Within 10-15 working days after received deposit
الأسعار
latest_price
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:
Product Details
Suncenter Fluid Control Equipment pays great attention to details of gas booster.
Enterprise Strength
  • Suncenter Fluid Control Equipment pays great attention to customer demand and strives to provide professional and quality services for customers. We are highly recognized by customers and are well received in the industry.
Company Advantages
1. The design of Suncenter air pressure testing adopts the advanced technologies and software which include computer-aided design (CAD), computer-aided modeling (CAM), etc.
2. The product is characterized by its excellent sealing effect. It tightly seals up the mating face, cutting off any leakage passages to exclude any medium.
3. Other features that are characteristic to this mattress include its allergy-free fabrics. The materials and the dye are totally non-toxic and will not cause allergies.
4. People will not find any loose thread or inferior seam or stitching on this product. All of its jointing parts are done professionally.

Gas booster pump system


Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


Suncenter stable hydrostatic pressure test marketing for safety valve calibration-1


DGS booster system = booster pump+ following valves, gages, and parts


Suncenter stable hydrostatic pressure test marketing for safety valve calibration-2



The hottest selling- model A and model C cabinet picture


Suncenter stable hydrostatic pressure test marketing for safety valve calibration-3
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGS-DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


Technical specification for DGS-DGD Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGS-DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


Technical specification for DGS-2DGD Series:


Model

Pressure boost ratio

Min. gas
   Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

DGS-2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

DGS-2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

DGS-2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


Technical specification for DGS-DGT Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGS-DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


Technical specification for DGS-2DGT series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

DGS-2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

DGS-2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

DGS-2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )


Suncenter stable hydrostatic pressure test marketing for safety valve calibration-4



Suncenter stable hydrostatic pressure test marketing for safety valve calibration-5
  • DGS series gas boosters working pictures


Suncenter stable hydrostatic pressure test marketing for safety valve calibration-6


DGS-DGD40 gas booster system for nitrogen gas spring filling

Suncenter stable hydrostatic pressure test marketing for safety valve calibration-7


DGS-DGT series gas boosters for gas cylinder transfer and filling


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd boasts many years of experience in manufacturing hydrostatic pressure test . We are regarded as a reputable manufacturer in the domestic market.
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd is equipped with a batch of the most advanced production machines.
3. Dongguan Suncenter Fluid Control Equipment Co., Ltd boasts the large service network, covering air pressure testing . Call! Following the core philosophy of gas booster compressor will make our dream of being the renowned Suncenter supplier come true. Call! Suncenter has been earnestly implementing the responsibility as a leading pressure booster pump manufacturer. Call! We can provide samples of hydraulic test bench for quality testing. Call!
The material of pressure booster pump allows air pressure testing to make itself air pressure testing.
pressure booster pump is designed as hydrostatic pressure test and it provides hydrostatic pressure test solution.
For its material, we used air pressure testing that was typical for hydraulic test bench.
Our pressure booster pump are constantly updated to follow the trend.
Materials of air pressure testing is actually quite gas booster compressor.
This product can be printed with any information. It provides a clear space for printing necessary and readable information, such as key features, advantages, and raw materials.
product_message
دردشة على الإنترنت 编辑模式下无法使用
اترك رسالتك inputting