Air driven refrigerant booster pump-SLM06


It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1.


When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.


No refrigerant heating from the motor.


Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard.


Suncenter model refrigerant pump industry for refrigeration industry-1
  • Air driven refrigerant booster pump-SLM06  


Driving air need

2-8bar

Pressure range

0-48bar

Pressure ratio

6:1

Flow rate

15L/min

Driving air size

ZG1/2

Increasing

63mm

Inlet size

ZG1/2

Stroke

60mm

Outlet size

ZG1/2

Noise

<75dB


DGS- SLM06 model refrigerant pump system


Suncenter model refrigerant pump industry for refrigeration industry-2
  • The standard system including following parts:

  • SLM06 model refrigerant pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS- SLM06 system = SLM06 booster pump+ following valves, gages, and parts


Suncenter model refrigerant pump industry for refrigeration industry-3


DGS- SLM06 model refrigerant pump system with 16L Accumulator


Suncenter model refrigerant pump industry for refrigeration industry-4
  • DGS- SLM06 model refrigerant pump system with 16L Accumulator


DGS-SLM06 model refrigerant pumps working picture


Suncenter model refrigerant pump industry for refrigeration industry-5
Suncenter model refrigerant pump industry for refrigeration industry-6



features

It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through  regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1. When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


  •   Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.

  •   No refrigerant heating from the motor. 

  •   Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard. 


video





After years of careful management, a set of scientific and rigorous production process has been established, and the quality is strictly controlled in all aspects of product design, production, quality inspection, and delivery. The refrigerant pump produced is fine in workmanship and high in quality , Strong practicability.
As a professional and responsible refrigerant pump manufacturer, we always put product quality first, insist on using high-quality raw materials and advanced production technology to manufacture refrigerant pump, and strictly control every production process to ensure that all refrigerant pump are qualified Products, to bring reliable quality assurance to customers.
refrigerant pump From raw material selection, production to processing, there are professionals to conduct testing. Not only that, refrigerant pump After the production is completed, it will be inspected by relevant national departments to ensure that it meets international standards and is of high quality. , high-quality products of excellent quality.
The freon pump manufactured by us with advanced design concepts not only strives for excellence in workmanship, scientific and reasonable design, but also has stable performance and durability, which can meet customers' needs for high-quality products.
freon pump The design is scientific and reasonable, the materials are exquisite, the workmanship is fine, durable, and the service life is long. It is a product of high quality and extraordinary quality.
Our skilled professionals supervise the quality control throughout the production, greatly guaranteeing the quality of the product. This product is very popular in many offices, clothes stores, printing shops, etc