تصبح خبير تحكم السوائل المرتفع من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  Suncenter industry-leading refrigerant pump industry for refrigeration industry
Suncenter industry-leading refrigerant pump industry for refrigeration industry

Suncenter industry-leading refrigerant pump industry for refrigeration industry

موك
1 Set
اسم العلامة التجارية
SUNCENTER
شهادة
ISO/CE/SGS
ضمان
13 Months
التعبئة والتغليف
By Plywood case
ميناء الشحن
Shenzhen/Hongkong
قسط
T/T,Western Union,Credit card.
طريقة المعاملة
EXW,FOB,DDP,CIF,CFR
مكان المنشأ
Guangdong Province, China (Mainland)
موعد التسليم
Within 10-15 working days after received deposit
الأسعار
latest_price
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:

Air driven refrigerant booster pump-SLM06


It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1.


When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.


No refrigerant heating from the motor.


Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard.


Suncenter industry-leading refrigerant pump industry for refrigeration industry-1
  • Air driven refrigerant booster pump-SLM06  


Driving air need

2-8bar

Pressure range

0-48bar

Pressure ratio

6:1

Flow rate

15L/min

Driving air size

ZG1/2

Increasing

63mm

Inlet size

ZG1/2

Stroke

60mm

Outlet size

ZG1/2

Noise

<75dB


DGS- SLM06 model refrigerant pump system


Suncenter industry-leading refrigerant pump industry for refrigeration industry-2
  • The standard system including following parts:

  • SLM06 model refrigerant pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS- SLM06 system = SLM06 booster pump+ following valves, gages, and parts


Suncenter industry-leading refrigerant pump industry for refrigeration industry-3


DGS- SLM06 model refrigerant pump system with 16L Accumulator


Suncenter industry-leading refrigerant pump industry for refrigeration industry-4
  • DGS- SLM06 model refrigerant pump system with 16L Accumulator


DGS-SLM06 model refrigerant pumps working picture


Suncenter industry-leading refrigerant pump industry for refrigeration industry-5
Suncenter industry-leading refrigerant pump industry for refrigeration industry-6



features

It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through  regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1. When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


  •   Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.

  •   No refrigerant heating from the motor. 

  •   Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard. 


video





The design process of Suncenter refrigerant pump is greatly enhanced. Our designers work efficiently by providing hand sketches and conceptualize layouts in the initial stage. The product, with strong adhesive holding power, can withstand heavyweight
The mockup of Suncenter refrigerant pump is designed by using CAD. This design method (CAD) allows our production team to bring out the mockup within hours. Pattern printing can be customized on this product
Suncenter manual oxygen pump is designed by our designers who carefully check the suitability of the chosen solution and give valuable advice concerning the selection of materials and finishes. Pattern printing can be customized on this product
The production process of Suncenter manual oxygen pump adopts the advanced packaging and printing method which has a long-lasting effect and creates unique visual benefits. It can be used by hands or automatic carton sealing machines
The surface treatment process of Suncenter manual oxygen pump are regarded as especially exclusive. This process is strictly carried out by adopting the highest package and printing standards. The product, with strong adhesive holding power, can withstand heavyweight
With a recognizable logo and distinctive shape, the product acts as an integral marketing strategy to glamorize an item in order to attract the consumer's attention. With strong acrylic adhesive, the product is distinguished by excellent holding force
رسالة المنتج
دردشة على الإنترنت 编辑模式下无法使用
اترك رسالتك inputting