تصبح خبير تحكم السوائل المرتفع من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  hydrostatic pressure test pressure free design for safety valve calibration
hydrostatic pressure test pressure free design for safety valve calibration

hydrostatic pressure test pressure free design for safety valve calibration
  • hydrostatic pressure test pressure free design for safety valve calibration
  • hydrostatic pressure test pressure free design for safety valve calibration
  • hydrostatic pressure test pressure free design for safety valve calibration
  • hydrostatic pressure test pressure free design for safety valve calibration

hydrostatic pressure test pressure free design for safety valve calibration

Apart from its delicate appearance, hydrostatic pressure test also attracts many customers for its gas pressure testing.
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:
Company Advantages
1. Suncenter hydrostatic pressure test is designed following the concept of striving for first-rate. It brings together the world’s finest materials and craftsmanship. It can be used for a broad variety of liquids, such as oil, water, and chemical
2. Suncenter's outstanding business team upholds a customer-oriented attitude and carefully listens to customers' needs. Its operation is safe with no heat, flame or spark risk
3. hydrostatic pressure test are recognized for their features of gas pressure testing. This product can be installed at any predetermined pressure

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


hydrostatic pressure test pressure free design for safety valve calibration-1



The hottest selling- Model C frame type cabinet picture


hydrostatic pressure test pressure free design for safety valve calibration-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


hydrostatic pressure test pressure free design for safety valve calibration-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Company Features
1. Apart from its delicate appearance, hydrostatic pressure test also attracts many customers for its gas pressure testing.
2. We follow the tenet of "sincerity and customer-orientation". We encourage staff to hold a sincere and wholehearted attitude towards customers services.
The tests for Suncenter gas pressure testing have been conducted. It has been tested in terms of flexibility, durability, accuracy, tolerances, fatigue resistance, etc.
Suncenter hydrostatic pressure test has to go through diverse tests. These tests include fatigue resistance testing, dimensional stability testing, chemical resistance testing, and mechanical testing.
The design of Suncenter gas pressure testing is of professionalism and sophistication. Its mechanical components, appearance, control system, and the whole body structure are carefully considered by the design teams.
Different inspection methods will be adopted on Suncenter hydrostatic pressure test. Both its internal mechanical parts and external parts will be inspected by visual examination, radiographic inspection, or magnetic crack detection.
Suncenter gas pressure testing is required to go through a series of quality tests. Its work blank, mechanical parts such as engine and motor, and materials have to be inspected by specific measurers or testing machines.
This product is safe to use. Its circuit including the main circuit, control circuit, and local circuit are designed accurately and efficiently.
رسالة المنتج
دردشة على الإنترنت 编辑模式下无法使用
اترك رسالتك inputting