تصبح خبير تحكم السوائل المرتفع من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  easy to use booster pump system transfer development for pressurization
easy to use booster pump system transfer development for pressurization

easy to use booster pump system transfer development for pressurization
  • easy to use booster pump system transfer development for pressurization
  • easy to use booster pump system transfer development for pressurization
  • easy to use booster pump system transfer development for pressurization
  • easy to use booster pump system transfer development for pressurization
  • easy to use booster pump system transfer development for pressurization
  • easy to use booster pump system transfer development for pressurization

easy to use booster pump system transfer development for pressurization

Our products have got global popularity and excellent reputation. It has flexibility without the use of unloaders or bypass valves
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:
Company Advantages
1. Suncenter co2 cylinder filling pump is crafted by skillful and experienced workers, with exquisite appearance. It has the capability of ultimate pressure, flow output horsepower
2. Our products have got global popularity and excellent reputation. It has flexibility without the use of unloaders or bypass valves
3. This product can always maintain a clean appearance. With no cracks or holes on the surface, it does not allow bacteria, viruses, or other germs to accumulate. It requires no electrical or mechanical drive connections

Air Driven Liquid CO2 Booster Pump-DGG/DGGD Series.


SUNCENTER pumps are air driven at a drive air pressure of 2bar to 8bar by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


easy to use booster pump system transfer development for pressurization-1



DGG Series Liquid CO2 Booster Pumps(Single acting)


easy to use booster pump system transfer development for pressurization-2
  • DGG Series Liquid CO2 Booster Pumps(Single acting)  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92

DGG130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14X1.5

1.47

DGG175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14X1.5

1.14


DGGD Series Liquid CO2 Pumps(Double acting)


easy to use booster pump system transfer development for pressurization-3
  • DGGD Series Liquid CO2 Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

2-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13

DGGD130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14*1.5

2.40

DGGD175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14*1.5

1.81


easy to use booster pump system transfer development for pressurization-4
  • Liquid carbon dioxide booster pump and pressurization equipment, commonly used in carbon dioxide supercritical extraction of various plant extracts, material foaming, and carbon dioxide fire extinguisher filling. Among them, carbon dioxide extraction is often used in biopharmaceuticals. Experimental research works by using a special pump for liquid carbon dioxide to pressurize carbon dioxide to a supercritical state, which is used to decompose various elements in plants for easy extraction.


DGGD series liquid CO2 pump working picture


easy to use booster pump system transfer development for pressurization-5
  • DGGD series liquid CO2 pump working picture



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable for liquid CO2/liquid+gas mixed CO2/Supercritical CO2

  •   For liquid CO2 cylinder transfer/filling

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





Company Features
1. As the leading booster pump system supplier, Suncenter has made big progress in the production of products.
2. Suncenter attaches great importance to the value of technical power.
3. Our goal is class service and our pursuance is to create world's first brand of co2 pump . Inquire online!
The design of Suncenter co2 pump is strictly conducted. It mainly covers the mechanical structure, spindles, and drive system, control and inspection systems, etc. The product can work for quite a long time
The development of Suncenter co2 cylinder filling pump adopts advanced technologies. They include computer-aided design, CNC machining, and sensor control technology. The product is equipped with an accurate print head
Advanced machining techniques have been adopted in Suncenter co2 pump production. It is fabricated under CNC machining, electrical discharge machining (EDM), laser cutting, and other treatments. The product can work for quite a long time
Quality debugging will be carried out when Suncenter co2 pump is produced. The debugging aspects include parts' connection, configuration, structural stability, and other mechanical performance. The product is praised for its anti-chemical resistance
Suncenter co2 pump goes through serious quality testing after it is produced. It has been certified under many international standards including CCC, CE, and RoHS. The product is manufactured by an experienced and professional design team
The product is highly resistant to rust. Its surface has been treated with an oxide protective layer to prevent the damage of wet environments. The product ensures stable and reliable performance