تصبح خبير تحكم السوائل المرتفع من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  Suncenter machine fire extinguisher refill type for fire extinguisher
Suncenter machine fire extinguisher refill type for fire extinguisher

Suncenter machine fire extinguisher refill type for fire extinguisher

موك
1 Set
اسم العلامة التجارية
SUNCENTER
شهادة
ISO/CE/SGS
ضمان
13 Months
التعبئة والتغليف
By Plywood case
ميناء الشحن
Shenzhen/Hongkong
قسط
T/T,Western Union,Credit card.
طريقة المعاملة
EXW,FOB,DDP,CIF,CFR
مكان المنشأ
Guangdong Province, China (Mainland)
موعد التسليم
Within 10-15 working days after received deposit
الأسعار
latest_price
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


Suncenter machine fire extinguisher refill type for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


Suncenter machine fire extinguisher refill type for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


Suncenter machine fire extinguisher refill type for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


Suncenter machine fire extinguisher refill type for fire extinguisher-4
Suncenter machine fire extinguisher refill type for fire extinguisher-5


video





Suncenter fire extinguisher refilling machine is professionally tailored. It adopts several pieces of advanced and high-efficient production equipment for prototyping, cutting, dyeing, sewing, and performance testing. Its streamlined design can effectively reduce tissue damage of the patients
The creation of Suncenter fire extinguisher refill is in compliance with both national and international standards, such as GS mark, DIN, EN, RAL GZ 430, NEN, NF, BS, or ANSI/BIFMA, etc. The product can be disinfected under high temperatures
The design of Suncenter fire extinguisher refilling machine is completed by a team of professional designers. It is finished by considering an advanced control system, engineering statistics, life cycle, utility, and manufacturability. The product can resist corrosion even in the presence of oxidizing acids
Suncenter fire extinguisher refilling machine meets international quality standards. Its is manufactured according to strict standards of lighting safety regulations. It is perfectly applicable to face, arm, abdominal, back, buttock and thigh
Suncenter fire extinguisher refill 's design is first a sketch, followed by a technical package or CAD drawing. It is done by our designers, who translate customer ideas into reality. The product is not prone to deformation after frequent uses
Based on the use of automated mechanical production equipment, our production efficiency has been greatly improved, and we can produce a large number of high-quality fire extinguisher refilling machine in a timely manner. In addition, we have also established a strict cost control system, and insist on strictly controlling the production cost of each link , prompting the production of fire extinguisher refilling machine to be extremely cost-effective.
رسالة المنتج
دردشة على الإنترنت 编辑模式下无法使用
اترك رسالتك inputting