كن خبير التحكم في السوائل ذات الضغط العالي من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  Suncenter lpg lpg pump type for safety valve calibration
Suncenter lpg lpg pump type for safety valve calibration

Suncenter lpg lpg pump type for safety valve calibration

موك
1 Set
اسم العلامة التجارية
SUNCENTER
شهادة
ISO/CE/SGS
ضمان
13 Months
التعبئة والتغليف
By Plywood case
ميناء الشحن
Shenzhen/Hongkong
قسط
T/T,Western Union,Credit card.
طريقة المعاملة
EXW,FOB,DDP,CIF,CFR
مكان المنشأ
Guangdong Province, China (Mainland)
موعد التسليم
Within 10-15 working days after received deposit
الأسعار
latest_price
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:
Company Advantages
1. Suncenter nitrogen pumping unit is highly recommended for its fine design. This product has a compact and robust design
2. Suncenter has been always paying close attention to the quality of the service. This product can be installed at any predetermined pressure
3. This product has a high electric safety level. During the production, it is thoroughly inspected for its insulation housing, overload protection system, and reliable electric conductors. Its output pressure can be easily adjustable
4. The product features an efficient retractable mechanism. The top and bottom rail of each panel incorporate an extruded aluminum mechanical seal to withstand the retracted or extended mode. The product can be mounted in any position

Compressed Air Driven Liquid Gas Booster Pump-DGG/DGGD Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Suncenter lpg lpg pump type for safety valve calibration-1



DGGD4 model special gas booster pump


Suncenter lpg lpg pump type for safety valve calibration-2
  • Application: various kinds of liquefying gas such as LNG, LPG, butane, propane, DME, etc  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

2bar-8 bar

4XPL

8bar-32bar

NPT1/2

NPT1/2

70.00


DGGD4 model LPG pump for cylinder transfer working picture


Suncenter lpg lpg pump type for safety valve calibration-3
  • DGGD4 model LPG pump for cylinder transfer working picture 



We could also make it into a booster pump station:DGS-DGGD4


Suncenter lpg lpg pump type for safety valve calibration-4
  • The standard system including following parts:

  • DGGD4 model gas booster pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS-DGGD4 =Suncenter booster pump(DGGD4)+following valves, gages, and parts


Suncenter lpg lpg pump type for safety valve calibration-5



features

  •  Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar 

  •   No airline lubricator required 

  •   Hydrocarbon free - separation between air and gas sections 

  •   Pressures to 80Mpa (11,600 psi)   

  •   Wide range of models with different ratios 

  •   Built-in-cooling on most models 

  •   Easy to install, operate and maintain 

  •   Best price / performance ratio 

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant not be higher than 8 bar


video





Company Features
1. We are backed by state-of-the-art factory. It is equipped with carefully selected, advanced, and sophisticated machinery and equipment. It allows us to produce high-quality products.
2. Quality, innovation, hard work and zeal to excel remain the steering force behind our business. These values have led us to become a company with a powerful manufacturing hub for customers.
Suncenter nitrogen pumping unit is designed considering its operation processes. They include stress points, support points, yield points, wear resistance, toughness, friction force, etc. This product can be applied in the various base materials, such as wood, metal, plastics, leather, and paper
Each production step of Suncenter lpg pump is carefully scrutinized. The quality of the product is guaranteed to meet the standards of the pool accessories industry. It has good temperature resistance performance
There are many ways that Suncenter nitrogen pumping unit is finished. These processes affect the end result by removing smaller fibers or burning off "fuzz". This product can keep the packaged contents safe and secured
The circuit board of Suncenter lpg pump is designed by adopting different technologies. It is carried out with the help of CAD and CAM software. The product has a super clear backing to show the brand logo
The workmanship of Suncenter nitrogen pumping unit requires particular skills of machinists. It has to be welded, stamped, and brazed by professional workers, and its parts are put together and fastened by hands during assembly. It can be used by hands or automatic carton sealing machines
From the perspective of the overall operation, analyze and control the cost of manpower, material resources, resources, etc. at a macro level, so as to improve the economic performance of lpg pump.
رسالة المنتج
دردشة على الإنترنت 编辑模式下无法使用
اترك رسالتك inputting