كن خبير التحكم في السوائل ذات الضغط العالي من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  portable oxygen pumps booster for-sale for safety valve calibration
portable oxygen pumps booster for-sale for safety valve calibration

Portable oxygen pumps booster for-sale for safety valve calibration

موك
1 Set
اسم العلامة التجارية
SUNCENTER
شهادة
ISO/CE/SGS
ضمان
13 Months
التعبئة والتغليف
By Plywood case
ميناء الشحن
Shenzhen/Hongkong
قسط
T/T,Western Union,Credit card.
طريقة المعاملة
EXW,FOB,DDP,CIF,CFR
مكان المنشأ
Guangdong Province, China (Mainland)
موعد التسليم
Within 10-15 working days after received deposit
الأسعار
latest_price
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:
Company Advantages
1. The materials of Suncenter haskel gas booster are sourced strictly in line with specification requirements for hardware tools&accessories. Any unqualified materials will be eliminated out. The product has reliable performance and simple access to the operation
2. People will find that even used for a long time, this product is able to still retain its original luster. It can be tailored to meet the specific requirements of customers
3. The product has been recognized internationally for its performance and quality. The product is consistently recognized as a reliable one in the industry

Compressed Air Driven Gas Booster Pump- DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


portable oxygen pumps booster for-sale for safety valve calibration-1



DGT series gas booster pumps(Double acting, double stage, single air drive head ):


portable oxygen pumps booster for-sale for safety valve calibration-2
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.  

  • DGT pumps are available with high quality seals, which provide significantly better service life  

  • All parts in contact with the gas are made of stainless steel. 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):


portable oxygen pumps booster for-sale for safety valve calibration-3
  • 2DGT series gas booster pumps(Double acting, double stage,double air driven heads ) 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar  

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •   Pressures to 80Mpa (11,600 psi)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof  

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





Company Features
1. Our factory boasts a series of advanced and sophisticated facilities. They operate smoothly under systematic management. This enables us to constantly manufacture high-quality products.
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd thinks highly of customer's feedback and suggestions for our oxygen pumps . Get price!
The design of Suncenter oxygen pumps requires the following knowledge of basic and engineering sciences. They include physics, mathematics, engineering mechanics, the strength of materials, the theory of machines, and thermodynamics.
Suncenter oxygen pumps is finally produced after several production processes. They are rough machining, fine machining, and finishing process, which are done to improve surface smoothness and size accuracy. We have professional QC team to strictly control quality of our products
A list of factors is taken into account of Suncenter haskel gas booster conception. They involve complexity, feasibility, optimization, tests, etc. of a machine. Prototype is made by CNC Milling,and the involved surface finishing including polishing, painting, the logo sticking
Suncenter haskel gas booster is professionally designed. Its design includes material design, system design, mechanical design and component structure design.
The manufacture of Suncenter oxygen pumps includes several important stages. They mainly include mechanical drawing design, metal materials preparation, parts fabrication&welding, assembly, and commissioning. Prototype is made by CNC Milling,and the involved surface finishing including polishing, painting, the logo sticking
oxygen pumps Exquisite material selection, fine workmanship, beautiful appearance, high quality, good thermal stability, corrosion resistance, sound insulation and heat insulation, can play the role of decoration, windproof, heat insulation, lighting and so on.
رسالة المنتج
دردشة على الإنترنت 编辑模式下无法使用
اترك رسالتك inputting