تصبح خبير تحكم السوائل المرتفع من الدرجة الأولى في العالم

Suncenter  >  AI - Page Sitemap  >  easy to use air driven liquid pump pneumatic types for machinery
easy to use air driven liquid pump pneumatic types for machinery

easy to use air driven liquid pump pneumatic types for machinery
  • easy to use air driven liquid pump pneumatic types for machinery
  • easy to use air driven liquid pump pneumatic types for machinery
  • easy to use air driven liquid pump pneumatic types for machinery
  • easy to use air driven liquid pump pneumatic types for machinery

easy to use air driven liquid pump pneumatic types for machinery

Suncenter pneumatic hydraulic pump high pressure has passed the following tests. It has been tested in terms of statics, dynamics, the strength of materials, vibrations, reliability, and fatigue.
latest_price_title
quantity_needed:
pieces
البريد الإلكتروني:

Compressed Air Driven Liquid Booster Pump-DGGD Series


We offer the most complete range of Air driven liquid pump models in the industry measured for:


Capability of ultimate pressure, flow or output horsepower.
++
easy to use air driven liquid pump pneumatic types for machinery-1
Compatibility with a broad variety of liquids, such as oil, water and chemical applications.
++


SUNCENTER pumps are air driven at a drive air pressure of 1bar to 8bar (14.5 psi to116 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.


SUNCENTER pumps are self priming. In general it is not necessary to use an air line lubricator. The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction effect, the inlet check valve is opened and the outlet check valve is closed. The down-stroke generates the pressure at the liquid side. The inlet check valve is closed and the outlet check valve is opened by the generated pressure. SUNCENTER liquid pumps cycle automatically, where the pressure is built up the numbers of cycles slow down, the pump stops automatically when the output pressure forces are equal. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump performance can be affected by a number of conditions, such as freezing of muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air line sizes and dirty filers. Don’t reduce the indicated port sizes and consult SUNCENTER for exact flow conditions not shown in charts.


easy to use air driven liquid pump pneumatic types for machinery-2



DGGD Series Liquid Pumps(Double acting, single air drive head)


easy to use air driven liquid pump pneumatic types for machinery-3
  • They are characterized by the same features as the DGG pumps single acting, single air drive head types, but they have less pulsations and deliver approx. 50 % more flow.


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

2-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13

DGGD130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14*1.5

2.40

DGGD175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14*1.5

1.81

DGGD255

255:1

2-8 bar

255XPL

2040

NPT1/4

M14*1.5

1.23

DGGD400

400:1

2-8 bar

400XPL

3200

NPT1/4

M14*1.5

0.79



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Pressures to 640Mpa (6400 bar)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant


video





The tests for Suncenter pneumatic hydraulic pump high pressure have been conducted. It has been tested in terms of flexibility, durability, accuracy, tolerances, fatigue resistance, etc.
Suncenter pneumatic hydraulic pump high pressure has to go through diverse tests. These tests include fatigue resistance testing, dimensional stability testing, chemical resistance testing, and mechanical testing.
The design of Suncenter air driven liquid pump is of professionalism and sophistication. Its mechanical components, appearance, control system, and the whole body structure are carefully considered by the design teams.
Different inspection methods will be adopted on Suncenter air driven liquid pump. Both its internal mechanical parts and external parts will be inspected by visual examination, radiographic inspection, or magnetic crack detection.
Suncenter air driven liquid pump is required to go through a series of quality tests. Its work blank, mechanical parts such as engine and motor, and materials have to be inspected by specific measurers or testing machines.
This product is safe to use. Its circuit including the main circuit, control circuit, and local circuit are designed accurately and efficiently.
رسالة المنتج
دردشة على الإنترنت 编辑模式下无法使用
اترك رسالتك inputting